Mitsubishi - 2.5kW
2.5kW
MSC-GA25VBHeat Pump
R410A Classic Wall Mounted System
Model Info
Qualified for Energy Technology ListR410A Compatible
  • Air Cleaning Filter is optional

Mitsubishi Electric’s new range of high specification, flat panel wall mounted models make use of traditional fixed speed technology, whilst providing extremely good value for money, costing approximately 30% less than the inverter equivalent. These units have extremely quiet sound levels, whilst also delivering economical air conditioning, with improved COP/EER figures. Ideal for use in any size room, this unit comes equipped with an automatic swing vane, allowing airflow to be extended to every corner of a room.

MSC-GA25VBMUH-GA25VBMSC MS(H) Controller
Hover your mouse over the red icons below to view a description of each feature:
Swing Vane modeAuto Vane Shutter - when unit is switched off the vane automatically closesInfra-red remote controller'I feel' control to adjust room temperature to a users unique preferenceOptimised Rotary or Scroll compressorEcono Cool - allows set temperature to be raised by 2 degrees C without any loss of comfort and a 20% gain in energy  efficiencyAuto-RestartQuiet OperationCatechin filter - improves air quality and prevents the spread of bacteria and viruses within the roomAir Cleaning filter - catches dust particles and contaminates, helping to keep the air fresh
 
Dimensions
MSC-GA25VB (Click to enlarge).
MSC-GA25VB
MUH-GA25VB (Click to enlarge).
MUH-GA25VB
MSC-GA25VB Indoor Unit
Capacity (kW): 
Heating (Nominal)3.0
Cooling (Nominal)2.65
Heating (UK)2.5
Cooling (UK)2.65
SHF R410A (Nominal)0.7
COP / EER (Nominal)3.66 / 3.23
Energy Label Heating / CoolingA / A
Width - mm815
Depth - mm244
Height - mm278
Weight - kg9
Airflow (m3/min) (Heating /Cooling) - Lo-Mi-Hi5.7-7.6-9.8 /5.1-6.4-7.9
Noise (dBA) (Heating /Cooling) - Lo-Mi-Hi25-32-39 /25-31-36
Pipe Size Gas mm (in)9.52 (3/8)
Pipe Size Liquid mm (in)6.35 (1/4)
Electrical Supply220-240v, 50Hz
PhaseSingle
Fuse Rating (BS88) - HRC (A)6
Power Input (kW) - Heating (Nominal)0.035
Power Input (kW) - Cooling (Nominal)0.035
Power Input (kW) - Heating (UK)0.035
Power Input (kW) - Cooling (UK)0.035
Running Current (A) - Heating / Cooling0.17 / 0.17
Interconnecting Cable No. Cores2 Core 12v
MUH-GA25VB Outdoor Unit
Width - mm800
Depth - mm285
Height - mm550
Weight - kg32
Noise (dBA) (Heating /Cooling) - Lo-Mi-Hi25-32-39 /25-31-36
Electrical Supply220-240v, 50Hz
PhaseSingle
Fuse Rating (BS88) - HRC (A)16
Power Input (kW) - Heating (Nominal)0.785
Power Input (kW) - Cooling (Nominal)0.785
Power Input (kW) - Heating (UK)0.711
Power Input (kW) - Cooling (UK)0.621
Starting Current (A)22
Running Current (A) - Heating / Cooling3.43 / 3.43
Mains Cable No. Cores3
Max Pipe Length (m)20
Max Height Difference (m)10
Charge (kg) - 7m0.8