Mitsubishi - 5.2kW
5.2kW
MXZ-2C52VAInverter Heat Pump
R410A Multi-Split Unit
Model Info
R410A Compatible
  • Up to 2 indoor units of mixed capacities may be connected to a single outdoor unit
  • Single outdoor unit for minimal noise and space impact
  • Units may be added within the capacity of the system as requirements change
  • Energy saving inverter controlled performance
This Multi-Split System allows up to 2 Mr Slim or M Series indoor units to be operated from a single outdoor unit.  This makes it an economic answer in multi-room applications, whilst also offering space saving benefits.
MXZ-2C52VA
Hover your mouse over the red icons below to view a description of each feature:
Optimised Rotary or Scroll compressorInverter control - adjusts performance to economically match the demand for heating or coolingHot Start - draught preventionReplace Technology Available
 
Dimensions
MXZ-2C52VA (Click to enlarge).
MXZ-2C52VA
MXZ-2C52VA 
Capacity (kW): 
Heating (Nominal) (Low - High)6.4 (1.0 - 7.0)
Cooling (Nominal) (Low - High)5.2 (1.1 - 6.0)
Heating (UK) (Low - High)5.3 (0.85 - 5.8)
Cooling (UK) (Low - High)5.15 (1.1 - 5.95)
COP / EER (Nominal)3.98 / 4
Energy Label Heating / CoolingA / A
Width - mm800
Depth - mm285
Height - mm550
Weight - kg38
Airflow (m3/min) (Heating /Cooling)33.3 /32.9
Noise (dBA) (Heating /Cooling) - Lo-Hi49-50 /46-49
Electrical Supply220-240v, 50Hz
Fuse Rating (BS88) - HRC (A)16
Interconnecting Cable No. Cores4
Power Input (kW) - Heating (Nominal)1.61
Power Input (kW) - Cooling (Nominal)1.3
Power Input (kW) - Heating (UK)1.47
Power Input (kW) - Cooling (UK)1.04
Starting Current (A)7.22
Running Current (A) - Heating / Cooling7.22 / 5.83
Charge R410A (kg) - 20m1.3
Piping Restrictions
Total Pipe Length (m)30
Max Pipe Length per Indoor Unit (m)20
Indoor to Outdoor Height (m)15
Powered by Enable Software